F-Gas Compliance & Regulatory Services

F-Gas · TM44 · Planned Maintenance

Air Conditioning Compliance, Made Simple

Over 30 years of keeping clients’ air conditioning safe, efficient and on the right side of the regulations, with clear records for every system.

Talk to Us About ComplianceCall 01704 833 755

AKS Air Conditioning
F-Gas

F-Gas certified, company-wide

Work on air conditioning and heat pump systems that contain fluorinated gas refrigerants must, by law, be carried out by certified engineers working for a certified company.

AKS holds full company F-Gas certification to install, maintain and service stationary refrigeration, air conditioning and heat pump equipment. We have the qualified people, the right tools and established procedures to minimise refrigerant emissions.

  • Leak checks at the intervals your systems require
  • Accurate refrigerant records for each system
  • Safe recovery and handling of refrigerants
Refrigerant pressure gauges on air conditioning pipework
Commercial rooftops with air conditioning plant
TM44

TM44 air conditioning inspections

In England and Wales, air conditioning systems with a total effective rated output over 12kW must have an energy assessment at least every five years, commonly known as a TM44 inspection. Building owners and managers who fail to comply can face penalties, and solicitors often ask to see the report when a property changes hands.

We can arrange your inspection with an accredited air conditioning energy assessor and carry out the recommended improvements.

  • Improved efficiency and lower energy use
  • Lower running costs
  • Reduced carbon emissions
Stay compliant all year

How we keep you compliant

Planned maintenance

PPM contracts with servicing, leak checks and records built in.

See maintenance plans →

Estate-wide surveys

Every unit across your sites graded, with gas type and charge recorded.

See the survey →

Upgrades

Replace older systems and refrigerants before they become a problem.

See upgrades →

F-Gas questions

Does F-Gas law apply to my air conditioning?

Most air conditioning and heat pump systems contain fluorinated gases (F-gases). If you own or operate the equipment, for example as a business or landlord, you are responsible for making sure it is leak-checked when required and that records are kept.

How often does my system need a leak check?

It depends on the system's refrigerant charge in tonnes of CO₂ equivalent. Under 5 tonnes: no legal leak check. 5 to 50 tonnes: at least every 12 months. 50 to 500 tonnes: at least every 6 months. 500 tonnes or more: at least every 3 months, and a fixed leak detection system must be fitted. Where a working leak detection system is fitted, the interval can be doubled.

How do I work out tonnes of CO₂ equivalent?

Multiply the refrigerant charge in kg by the refrigerant's global warming potential (GWP), then divide by 1,000. For example, 2.4 kg of R410A (GWP 2,088) is about 5 tonnes CO₂e, which is enough to need a yearly leak check.

Who can carry out an F-Gas leak check?

Leak checks must be carried out by an F-Gas certified engineer. AKS Air Conditioning is a REFCOM registered, F-Gas certified company.

What records do I need to keep?

For systems of 5 tonnes CO₂e or more, keep a record of the refrigerant type and quantity, any refrigerant added or recovered, the dates and results of leak checks, and who carried out the work. Keep the records for at least 5 years.

Can I still use my R22 air conditioning?

You can keep running it, but R22 has not been allowed for servicing or topping up in the UK since 2015. If the system leaks or develops a fault, it may not be repairable, so it is worth planning a replacement.

Not sure where you stand?

Tell us about your systems and we’ll tell you what you need to stay compliant.